Water heater size calculator

Count the hot water your household uses in its busiest hour to get the first hour rating (FHR) a tank water heater needs, then size a tankless unit by flow and temperature rise in BTU/h and kW.

Peak hour (tank)

20 gal each

20 gal each

2 gal each

3 gal each

7 gal each

25 gal each (top-loader)

Tankless

2.5 GPM each

1.5 GPM each

°F

40 north, 55 middle, 70 south

Peak-hour hot water

80 gal

80 gallons in the peak hour → FHR ≥ 80

Minimum first hour rating (FHR)
80 gal
Choose a heater whose EnergyGuide FHR is at least this
Typical tank
50 gal gas or 80 gal electric
FHR 61–80 gal; check the label, FHR varies by model
Tankless flow at once
6.5 GPM
2 × 2.5 + 1 × 1.5 GPM
Temperature rise
65°F
120°F set point − 55°F incoming
Tankless output needed
211,419 BTU/h
GPM × 60 × 8.34 lb × rise
Electric tankless size
62.0 kW
BTU/h ÷ 3,412
  • An electric tankless at 62.0 kW is impractical for most homes (150 A+ at 240 V); use gas or more than one unit.
  • Over 199,000 BTU/h exceeds a single residential gas tankless; plan two units or reduce simultaneous use.
  • FHR is on the EnergyGuide label; sizing by tank gallons alone ignores recovery rate.
Peak hour 80 gal; tankless 6.5 GPM at 65°F riseTank filled to 80 gallons against 40, 50 and 80 gallon marks; 50 gal gas or 80 gal electric. Tankless: 6.5 GPM from 55°F to 120°F needs 211,419 BTU/h (62.0 kW).Tank: busiest hourgal40508080 gal01FHR band 61–80 gal50 gal gas or 80 gal electricTankless: all at oncetanklessheaterout 120°FΔT 65°F026.5 GPMin 55°F03211,419 BTU/h62.0 kW04
Default example: 80 gal peak hour against 40, 50 and 80 gal marks (left); 6.5 GPM from 55°F to 120°F through a tankless heater (right).
  1. 01 Peak-hour gallons = minimum first hour rating (FHR)
  2. 02 Temperature rise: 120°F out minus incoming
  3. 03 Flow running at once, GPM
  4. 04 Tankless output needed, BTU/h and kW

How water heater size is calculated

A tank water heater runs out when your busiest hour uses more hot water than the heater can deliver in that hour. The DOE method adds up that hour and compares it with the heater's first hour rating (FHR).

peak-hour gallons = 20 × showers + 20 × baths + 2 × shaves + 3 × hand dishwashing or food prep + 7 × dishwasher loads + 25 × washer loads

first hour rating needed ≥ peak-hour gallons

A tankless heater has no stored water, so it has to heat everything flowing at the same moment. Size it by flow and by how far it has to raise the water temperature.

flow (GPM) = 2.5 × showers running + 1.5 × faucets running

temperature rise = 120°F − incoming water temperature

BTU/h = GPM × 60 min × 8.34 lb per gallon × rise

kW = BTU/h ÷ 3,412

The 60 × 8.34 part is 500.4, which is why installers round it to "GPM × 500 × rise".

Worked example: 80 gallon peak hour

The calculator opens on a household's busiest hour: 2 showers, 1 shave, 2 hand dishwashing or food-prep uses, 1 dishwasher load and 1 clothes washer load, with 2 showers and 1 faucet running at once and 55°F water coming in.

  1. Peak hour: 2 × 20 + 1 × 2 + 2 × 3 + 1 × 7 + 1 × 25 = 80 gallons, so look for an FHR of at least 80.
  2. That falls in the 61–80 gallon band: typically a 50 gal gas or 80 gal electric.
  3. Tankless flow: 2 × 2.5 + 1 × 1.5 = 6.5 GPM. Rise: 120 − 55 = 65°F.
  4. Output: 6.5 × 60 × 8.34 × 65 = 211,419 BTU/h, or 62.0 kW.

That is more than one residential gas tankless unit delivers (199,000 BTU/h) and far beyond a practical electric unit, so this household would either stagger showers, install two tankless units or stay with a tank.

Peak-hour gallons and tank sizes

Use these DOE figures to estimate your busiest hour, usually a weekday morning. Count only what really happens in the same hour.

Hot water per use in the peak hour (U.S. DOE).
UseGallons
Shower20
Bath (DOE’s earlier worksheet)20
Shaving2
Hand dishwashing or food prep3
Dishwasher load7
Clothes washer load (top-loader; about 15 for a front-loader)25

The calculator maps the FHR you need to a typical tank. The first hour rating varies by model, so treat the tank as a starting point and confirm the FHR on the label.

Typical tank by first hour rating needed (gallons).
FHR neededTypical tank
up to 6040 gal gas or 50 gal electric
61–8050 gal gas or 80 gal electric
81–10075 gal gas or high-input 50 gal gas
over 100100 gal, two heaters, or tankless
Typical first hour ratings (industry typical, approximate).
TankTypical FHR, gal
40 gal gas65–75
50 gal gas80–90
50 gal electric60–65
80 gal electric75–80

Tankless sizing tips

  • Use your local ground-water temperature: about 40°F in the north, 55°F in the middle of the country and 70°F in the south. Size for winter, when the inlet is coldest. If you don't know it, the DOE suggests assuming 50°F.
  • Count only fixtures that really run together. A second shower adds 2.5 GPM; at a 65°F rise that is 81,315 BTU/h on its own.
  • An electric tankless unit above about 36 kW (122,832 BTU/h) usually needs 150 A or more at 240 V. Check the panel and service before you buy.
  • A gas unit needs the right gas pipe size and venting for its full input. The manufacturer's installation manual sets both.
  • Tankless flow ratings drop as the rise goes up. Read the GPM the unit delivers at your rise, not the headline number.

Hire a licensed plumber for gas lines, venting and relief valves, and an electrician for any new circuit; many areas also require a permit to replace a water heater.

Sources

Frequently asked questions

What size water heater do I need?

Size a tank by its first hour rating, not its gallons. Add up the hot water used in your busiest hour (the DOE uses 20 gal per shower, 20 per bath, 25 per clothes washer load and 7 per dishwasher load) and pick a heater whose FHR is at least that total.

What is a first hour rating?

The first hour rating is how many gallons of hot water a tank heater can deliver in one hour starting with a full tank. It combines tank size and recovery rate, and it is printed on the yellow EnergyGuide label.

What FHR does a family of four need?

It depends on the busiest hour, not the head count. Two showers, a shave, two hand-washing or food-prep uses, a dishwasher load and a washer load come to 80 gallons with the DOE figures, so that household needs an FHR of at least 80. Back-to-back showers push it higher.

How do you size a tankless water heater?

Multiply the flow you run at once (GPM) by 500 and by the temperature rise. Two showers and a faucet (6.5 GPM) with a 65°F rise need about 211,000 BTU/h.

Why does incoming water temperature matter so much?

The heater has to lift every gallon from the ground-water temperature to the 120°F set point. Going from a 70°F inlet to a 40°F inlet raises the rise from 50°F to 80°F, which needs 1.6 times the output for the same flow.

Can my house run an electric tankless water heater?

Whole-house electric tankless units draw roughly 18 to 36 kW, and most homes cannot support more than one. Above about 36 kW the electrical service usually needs an upgrade, so gas or point-of-use units are the usual answer.

Is a bigger tank always better?

No. A larger tank costs more to buy and loses more heat while it sits. Match the first hour rating to your peak hour; a gas heater with fast recovery can beat a larger electric tank.