Insulation calculator

Enter the area, the insulation and the R-value you are aiming for. Get the number of batts and bags for walls and floors, or the depth and bags of blown-in fiberglass or cellulose for an attic, with the IECC 2021 climate-zone minimums for reference.

Area
ft²

Attic floor, or wall length × height minus large openings.

Product

Used for every area. Run a different product or R-value separately.

Batts
in

On center. Ignored for blown-in.

in

93 in precut studs; 48 or 96 in for floors and attics.

Advanced options
Blown-in bag chart
ft²

Square feet per bag at your R-value, printed on the bag. 0 = typical.

Bags

20 bags

1,000 ft² ÷ 51.0 ft² per bag, rounded up

Settled depth
15.2 in
R-38 ÷ 2.5 per inch
Volume of insulation
1,266.7 ft³
Coverage per bag
51.0 ft²
Typical blown fiberglass bag: 51 ft² at R-38 × 38 ÷ 38. Bag coverage varies by brand and R-value; read the chart on the bag and enter it for an exact count.
Area
1,000 ft²
IECC 2021 minimums by climate zone are in the table below; local codes may differ.
Blown fiberglass to R-38: 20 bags, 15.2 in deepAttic floor section: 2×6 ceiling joists 24 in on center over drywall, blown fiberglass blown 15.2 in deep for R-38.15.2 in010203Attic floor section, R-38 blown fiberglass
Default example: 1,000 ft² attic floor with blown fiberglass to R-38, 15.2 in deep over 2×6 joists, drawn to scale. Batts switch the diagram to a section through the framing bays.
  1. 01 Settled depth for R-38: 15.2 in
  2. 02 Loose fill: blown fiberglass at R-2.5 per inch
  3. 03 Ceiling joists and drywall

How insulation is calculated

Enter each attic, wall or floor as its own area with “+ Add another area”. The areas are added together and the batts or bags are rounded once for the whole job. Every area uses the same insulation and R-value, so run a different product, such as batts in the walls and blown-in in the attic, as a separate calculation.

Batts are counted by framing bay. One batt fills one cavity, so each batt covers the stud spacing times the batt length, including the framing it sits between.

wall covered per batt (ft²) = (spacing ÷ 12) × (batt length ÷ 12)

batts = area ÷ wall covered per batt, rounded up

bags = batts ÷ 10, rounded up

nominal thickness (in) = R-value ÷ 3.2

Blown-in insulation is sized by depth. Divide the target R-value by the R per inch of the material to get the settled depth, then use the coverage per bag for that R-value to count bags.

depth (in) = R-value ÷ R per inch (2.5 blown fiberglass, 3.6 cellulose)

volume (ft³) = area × depth ÷ 12

coverage per bag (ft²) = bag chart value, or typical coverage at R-38 × 38 ÷ R-value (51 ft² fiberglass, 24 ft² cellulose)

bags = area ÷ coverage per bag, rounded up

The typical coverage assumes a fiberglass bag that covers 51 ft² at R-38 (a cellulose bag about 24 ft²) and spreads thinner or thicker in proportion. Real bag charts fall off a little faster than that at high R-values (a few percent at R-60 for fiberglass, about 10% for cellulose), and brands differ, so enter the figure from your bag's chart under advanced options for an exact count.

Worked example: 1,000 ft² attic to R-38

The calculator opens on a 1,000 ft² attic floor with blown fiberglass to R-38.

  1. Depth: 38 ÷ 2.5 = 15.2 in settled.
  2. Volume: 1,000 × 15.20 ÷ 12 = 1,266.7 ft³.
  3. Coverage per bag: 51 × 38 ÷ 38 = 51.0 ft².
  4. Bags: 1,000 ÷ 51.0 = 20 bags.

The same 1,000 ft² of wall in R-13 batts at 16 in on center with 93 in batts: each batt covers 1.333 × 7.75 = 10.33 ft², so you need 97 batts, or 10 bags of 10. The nominal thickness works out to 4.1 in, but a real R-13 batt is a denser 3-1/2 in product made to fill a 2×4 wall.

Minimum R-values by climate zone

These are the IECC 2021 prescriptive minimums for new homes, with the settled depth each ceiling value takes in blown fiberglass and cellulose. Find your zone by county in IECC Table R301.1. In zone 5, for example, ceilings call for R-60 and floors R-30.

IECC 2021 Table R402.1.3 minimums; depths = R ÷ R per inch
ZoneCeilingBlown fiberglass, inCellulose, inWood-frame wallFloor
0 and 1R-3012.08.313 or 0+10ciR-13
2R-4919.613.613 or 0+10ciR-13
3R-4919.613.620 or 13+5ci or 0+15ciR-19
4 except MarineR-6024.016.730 or 20+5ci or 13+10ci or 0+20ciR-19
5 and Marine 4R-6024.016.730 or 20+5ci or 13+10ci or 0+20ciR-30
6R-6024.016.730 or 20+5ci or 13+10ci or 0+20ciR-30
7 and 8R-6024.016.730 or 20+5ci or 13+10ci or 0+20ciR-38

“13+5ci” means R-13 in the cavity plus R-5 continuous insulation over the framing. Section R402.2.1 lets R-38 satisfy an R-49 ceiling, and R-49 satisfy R-60, where full-height insulation covers the whole ceiling and runs over the top plates at the eaves. States and cities amend the code; confirm the edition in force with your building department.

Batt thickness by R-value

Typical fiberglass batts (manufacturer data; check the label)
R-valueThicknessTypeTypical cavity
R-133-1/2 inStandard2×4 wall
R-153-1/2 inHigh-density2×4 wall
R-196-1/4 inStandard2×6 wall (compressed to 5.5 in it performs at about R-18)
R-215-1/2 inHigh-density2×6 wall
R-309-1/2 in to 10 inStandard2×10 floor or attic
R-3812 in to 12-1/2 inStandard2×12 or attic
R-4913-1/2 in to 14 inStandardAttic (single R-49 batt, or two layers)
R-6019 inStandardAttic: two layers (for example R-30 + R-30); no common single R-60 batt

Measuring and buying tips

  • For an attic, measure the ceiling below, length times width, and skip the eaves past the walls. For walls, multiply length by height and subtract big openings like garage doors and patio doors; leave ordinary windows in, since the offcuts fill around them.
  • Match the batt to the framing: 15 in wide batts for 16 in on center, 23 in for 24 in. Use 93 in precut batts for 8 ft walls and 48 or 96 in for floors and attics.
  • Blown-in settles. The bag chart lists both the installed and the settled depth; size to the settled depth and set depth rulers on the joists before you start.
  • Air-seal top plates, plumbing and wiring holes, and the attic hatch before insulating, and keep loose fill back from recessed lights that are not IC-rated and from flues.
  • Keep soffit vents open with baffles so the attic still breathes once the fill is deep.

When to hire a pro

Get an insulation contractor for knob-and-tube wiring, vermiculite (it can contain asbestos), signs of moisture or mold, or an attic too low to work in safely. A blower rental is fine for an open attic, but a pro will dense-pack closed walls and can run a blower-door test to find the air leaks.

Sources

Frequently asked questions

How many inches of insulation do I need for R-38?

About 15.2 in of blown fiberglass (R-2.5 per inch) or 10.6 in of cellulose (R-3.6 per inch). R-38 fiberglass batts are about 12 in to 12-1/2 in thick. Always go by the settled depth on the bag chart.

What R-value per inch do fiberglass and cellulose give?

Typical figures are R-3.2 per inch for fiberglass batts, R-2.5 for blown fiberglass and R-3.6 for cellulose. Products vary, so the label wins.

How deep should R-49 cellulose be?

About 13.6 in settled. Blown fiberglass needs about 19.6 in for the same R-49 because it gives less R per inch.

How many batts do I need for a wall?

Count by framing bay. At 16 in on center, a 93 in batt covers about 10.3 ft² of wall, framing included, so 1,000 ft² takes 97 batts, or 10 bags of 10.

How many bags of blown-in insulation do I need?

Divide the attic area by the coverage per bag at your R-value from the chart printed on the bag. A typical loose-fill fiberglass bag covers about 51 ft² at R-38, so 1,000 ft² takes about 20 bags. A cellulose bag covers only about 24 ft² at R-38, so cellulose takes roughly twice as many bags.

What R-value does the IECC require in my attic and walls?

IECC 2021 Table R402.1.3 calls for R-49 to R-60 ceilings everywhere outside zones 0 and 1 (R-30 there). Wood-frame walls need R-20 (or R-13+5ci) in zone 3 and R-30 (or R-20+5ci) from zone 4 up, where ci is continuous insulation over the framing. Check which edition your town has adopted.

Can I put R-19 batts in a 2×6 wall?

R-19 batts are 6-1/4 in thick, so they compress in a 5-1/2 in 2×6 cavity and lose some R-value. R-21 high-density batts are made to fit that cavity at full thickness.